Author Guidelines
How to prepare and submit a manuscript to CYBIA.
On this page
Before you submitArticle typesManuscript structureMethods and reportingFormattingReferencesDeclarationsHow to submitAfter submissionBefore You Submit
By submitting, the corresponding author confirms on behalf of all authors that:
- The manuscript is original, has not been published before (except as a preprint or thesis), and is not under consideration by another journal.
- The topic fits the Focus and Scope.
- Overall similarity is below 20%, with no more than 3% from any single source (Plagiarism Policy).
- All authors meet the authorship criteria and have approved the submission and the author order.
- Every author has an ORCID iD, entered in the submission form with a full affiliation and country.
- Research involving human participants, personal data, or animals has the required consent and ethical approval.
- Any use of generative AI is disclosed under the Generative AI Policy.
Article Types
Manuscript Structure
Research articles follow the structure below. Reviews may replace Method and Results with the review protocol and synthesis.
Methods and Reporting
Reviewers for CYBIA pay particular attention to the following points:
- State the threat model: assets, adversary capabilities, assumptions, and what is out of scope.
- Describe the experimental environment (testbed, network topology, tools and versions) and the datasets used, with their versions (for example CIC-IDS2017 or UNSW-NB15).
- Report detection results with false-positive and false-negative rates, not accuracy alone, and test on data not used for training.
- Compare with recent, relevant defences or detectors under the same conditions.
- For governance, risk, and compliance studies, describe the framework applied (for example ISO/IEC 27001, NIST CSF, COBIT), the sample, and the validity of the instruments.
- Confirm that testing was authorized and that any vulnerability was responsibly disclosed before submission.
Please follow the relevant reporting guideline: PRISMA 2020 for systematic reviews.
Formatting
- File: Microsoft Word (.docx) prepared with the CYBIA template; LaTeX users may contact the editor.
- Language: clear academic English, checked by a proficient speaker or professional editing service before submission. Manuscripts with language problems that obscure the meaning are returned before review.
- Headings: numbered, at most three levels (1., 1.1., 1.1.1.).
- Tables: editable (not images), numbered, with a title above; explain abbreviations in a note below.
- Figures: at least 300 dpi, readable when printed in grayscale, numbered, with a caption below; cite the source of any figure not created by the authors and obtain permission where needed.
- Equations: created with the Word equation editor, numbered on the right, and every symbol defined.
- Units and numbers: SI units; a period as the decimal separator; define abbreviations at first use.
- Footnotes: avoid; integrate the information into the text.
References
- Use IEEE style and a reference manager (Mendeley, Zotero, or EndNote).
- At least 25 references for research articles, of which at least 80% are journal articles or peer-reviewed proceedings from the last ten years.
- Every reference is cited in the text and every citation appears in the reference list.
- Include the DOI of every reference that has one.
- Cite the original source, not a secondary one; avoid predatory journals, unpublished theses, and non-scholarly websites.
- Self-citation should be limited to what is genuinely relevant.
- References must be written in Latin script. For a work not in English, give the original title transliterated, followed by an English translation in square brackets, and indicate the language.
Cite references in the text with numbers in square brackets, for example [1] or [2]–[4], numbered in order of first appearance.
Required Declarations
Place these statements before the references. Use the wording below as a model.
How to Submit
- Register or log in on this website and choose Make a Submission.
- Upload the anonymized manuscript (without author names, affiliations, acknowledgments, or identifying file properties).
- Upload a separate title page with full author information and the declarations.
- Enter the metadata exactly as in the manuscript: title, abstract, keywords, and every author with affiliation, country, and ORCID iD. This metadata is what indexing services receive.
- Optionally upload a cover letter explaining the contribution and suggesting two to three potential reviewers without conflicts of interest.
- Confirm the submission checklist and the copyright terms, then submit.
After Submission
Screening
Scope, template, declarations, and similarity check (about one week).
Peer review
Double-blind, at least two reviewers; first decision in about [4–6 weeks].
Revision
Revised manuscript with a point-by-point response within [two weeks] (minor) or [four weeks] (major).
Acceptance
Final decision by the editor; license agreement.
Production
Copyediting, layout, author proof check within three days, DOI, and online publication.
Accepted articles show the submission, acceptance, and publication dates. Track progress in the journal system; questions go to [cybia@resincen.org] with the submission ID.
Make a SubmissionDownload Template
Cyber Security and Information Assurance (CYBIA) · Last updated: [DD Month 2026]
